10 KLD STP price in Chennai – ASP Technology - RRR ENVIRO SYSTEMS - Key Design Parameters
- Capacity: 10 KLD (10,000 Litres Per Day)
- Technology: ASP – Activated Sludge Process
- Daily Operating Hours: 20 Hours
- BOD Inlet: 250 – 300 mg/L → Outlet < 10 mg/L
- TSS Inlet: 250 – 350 mg/L → Outlet < 20 mg/L
- pH Range: 6.5 – 8.5
- Power Requirement: 3 – 4 HP
- Fully automatic / semi automatic options available
Flow Diagram (ASP Process)
🚽 Sewage Generation →
🧱 Bar Screen & Oil/Grit Trap →
🟦 Collection & Equalization Tank →
🔁 Raw Sewage Transfer Pump →
🌬 Aeration Tank (No Media in ASP) →
🌀 Secondary Settling Tank →
🔄 Return Sludge Pump →
💧 Clarified Water Tank →
🏗 Pressure Sand Filter →
🪵 Activated Carbon Filter →
🧴 Hypo Dosing →
✅ Final Treated Water Tank (Gardening / Flushing)
Tank & Equipment Details
| Component | Material (MOC) |
|---|---|
| Collection / Equalization Tank | RCC / MSEP / FRP with Rubber Lining |
| Aeration Tank | RCC / MSEP / FRP |
| Secondary Settling Tank | RCC / MSEP / FRP (No clarifier mechanism for 10 KLD) |
| Filters | FRP / MSRL |
| Blower | Roots Type / Twin Lobe |
| Transfer & Return Pumps | Cutter / Sewage Type |